Home ProductsEpoxy Resin Worktop

High Temp Non Toxic Science Lab Countertops Acid / Alkali Resistant 1500*750 Size

High Temp Non Toxic Science Lab Countertops Acid / Alkali Resistant 1500*750 Size

  • High Temp Non Toxic Science Lab Countertops Acid / Alkali Resistant 1500*750 Size
  • High Temp Non Toxic Science Lab Countertops Acid / Alkali Resistant 1500*750 Size
High Temp Non Toxic Science Lab Countertops Acid / Alkali Resistant 1500*750 Size
Product Details:
Place of Origin: CHINA
Brand Name: SHENGSTONE
Certification: CE,SGS
Payment & Shipping Terms:
Minimum Order Quantity: negotiation
Price: negotiation
Packaging Details: Wood Box Or Pallet
Delivery Time: 15-40 work days
Payment Terms: T/T
Supply Ability: 10000 Square Meter per Month
Contact Now
Detailed Product Description
Material: Epoxy Resin Color: Black
Thickness: 16mm,19mm,25mm Usage: Hospital, School, Company, Research Institute
Function: High Temperature Resistant Countertop Edging: Flat Edge / Eased Edge
Surface: Matte Place Of Origin: China
Type: Laboratory Parts Customized: Customized
High Light:

epoxy resin lab countertops

,

chemical resistant countertope

Laboratory Acid And Alkali Resistant Black Epoxy Resin Worktop Flat Edge / Eased Edge Worktop

 

1. Product Description:

 

  Color: Black

 

  Size: 1500*750

  Thickness: 19 mm

  Surface: Matt

  Mini order : 50 Square meters

  Delivery time: 15-30 days after receipt of deposit.

 

2. Properties of Epoxy Resin Worktop

 

A) 24 hours super corrosion resistance

Inert materials have strong resistance to most corrosive chemicals.

Resistance to high temperature

B) And laboratory common high temperature 600 degrees, not foaming, not broken, especially suitable for a long time to place the combustion furnace ventilation cabinet.

 

C). Absolute moisture

The epoxy resin worktop with low water absorbition, does not absorb moisture in the air, the installation will not warp deformation, especially suitable for the operation of splash zone.

 

D). Pollution resistance

Surface is smooth, no stoma, not to hide the dirt, effectively restrain bacterial growth, such as the SARS virus, etc.,especially suitable for the medicine and biological laboratories.

 

E). Safe and reliable

Do not contain asbestos ingredient, nonflammable, non-conductive, do not produce poisonous gas when heated, will not violate the safety and health of operator.

 

F). Durable

One core, not to take off layer, not inflation, not cracked,surface scratches can be repaired after renovation

 

G). High performance to price ratio

Unique 19mm thickness, the market is the highest price of the laboratory table system.

 

H). Beautiful appearance

Smooth surface (MATT finish) , light reflection, easy to clean, easy maintenance.

 

I). Uniform color

Ensure the color of different batches of products is permanent, can be used for multi color selection.

 

epoxy resin worktop High temperature resistance

 

3. Common specification sheet (Unit : mm)

Long
Wide Thickness
1200 700(750) 16/19/25
1500 700(750) 16/19/25
1800 700(750) 16/19/25
2400 700(750) 16/19/25
3000 700(750) 16/19/25

 

epoxy resin edge

 

4. Chemical Test Results for Black

 

No. Chemical Reagent Actual Rating
1 Carbon Tetrachoride 1
2 Chloroform 1
3 Chromic Acid,60% 1
4 Cresol 0
5 Dichlor Acetic Acid 0
6 Dimethylformanide 0
7 Dioxane 0
8 Ethyl Ether 0
9 Formaldehyde,37% 0
10 Formic Aicd,90% 0
11 Furfural 0
12 Gasoline 0
13 Hydrofluoric Acid,37% 1
14 Hydrofluoric Acid,48% 3
15 Hydrogen Peroxide,30% 0
16 Lodine,Tincture of 0
17 Methyl Ethyl Ketone 0
18 Methylene Chloride 1
19 Mono Chlorobenzene 1
20 Naphthalene 0
21 Nitric Acid,20% 0
22 Nitric Acid,30% 0
23 Nitric Acid,70% 0
24 Phenol,90% 0
25 Phosphoric Acid,85% 0
26 Silver Nitrate,Saturated 0
27 Sodium Hydroxide,10% 0
28 Sodium Hydroxide,20% 0
29 Sodium Hydroxide,40% 0
30 Sodium Hydroxide,Flake 0
31 Sodium Sulfide,Saturated 0
32 Sulfuric Acid,33% 0
33 Sulfuric Acid,77% 0
34 Sulfuric Acid,96% 3
35 Sulfuric Acid,77% and Nitric Acid 70%, 0
equal parts
36 Toluene 0
37 Trichloroethylene 1
38 Xylene 0
39 Zinc Chloride, Saturated 0
Rating scale: Level 0--No detectable change
Level 1--Slight change in color or gloss
Level 2-- Slight surface ething or severe staining
Level 3--Pitting,cratering,swelling, or erosion of coating.Obvious and significant
deterioration
Acceptance level: Laboratory grade finishes shall result in no more than four level 3 conditions.
Suitability for a given application is dependent upon the chemicals used in a given laboratory

 

 

Contact Details
shengstone international limited

Contact Person: Ms. Lee

Tel: +8618950079139

Send your inquiry directly to us (0 / 3000)

Best Products